An instructor found this damaged locking loop while inspecting the gear of a licensed jumper who was participating in a canopy course. When looking at the front of the riser and 3-ring assembly, the damaged loop was obscured from view. The instructor found it while looking more carefully at the back of the riser during a gear check. The damage likely occurred when the locking loop came into contact with a rough surface during a landing or during packing. Jumpers should check both the fronts and backs of their risers when inspecting their gear.